How do you connect EVE to the LCD?

Signals required are R [7:2] or [7:0], G [7:2] or [7:0], B [7:2] or [7:0], PCLK, DE, VSYNC and HSYNC. R, G, B signals locations are user configurable. In addition, endian of R, G, B signals are also configurable. These will make PCB routing much easier.